Feature of mounts
Pneumatic elastomeric mounts isolation the vibration and shock of the machine form the floor.It can also reduce the influencess from vibration reduction.It eliminates the noise transferred from the floor or due to the resonance of building.
Machine are stationary on the floor without anchors.Therefore the installation cost and time can be greatly saved. The layout can be easily changed to improve the prodctivity.Machines can set up on the second floor.
Data parameter
part No. M Aduust height static load kg | | | |
PS 073-64 M8*80 ±6.5 450 | | | |
PS 105-64 M8*80 ±6.5 1350 | | | |
PS 120-89 M12*100 ±6.5 2670 | | | |
PS 190-89 M12*100 ±6.5 5340 | | | |
PS 267-89 M16*120 ±6.5 10700 | | | |
PS 400-89 M16*120 ±6.5 22000 | | | |
PS pneumatic anti-vibration machine mounts show
Application
Precision machine tool,Coordinate measuring machine,Accurate test bed,100/min-500min Punch,Air compressor,Air pump and required special vibration isolation of equipments.
How to install
Place the mounts under the anchor of the machine,insert center bolt and engate threads in mount.Hand tightening is adequate at this point.Sequentially pressurzation of isolator rhtough valve until dimension is 3 mm for each mount.Tighten the nuts.Continue sequential pressurization of each mount so that dimension is 7 mm,Then aadjust the level of machine.Check each mount for overall height which should be within H ±6mm.
Whenever machine is to be removed from mounts,Deflate mounts before removal of load.
Packing and shipping